Product Catalogue 2018 Air Handling Units Daikin

Product catalogue 2018 air handling units daikin

File Name: 810_Air handling units_Product catalogue.pdf

File Size: 1.02 MB

File Type: Application/pdf

Category: It

Uploaded: 7 months

Last Modified: 7 months

Status: Available

Last checked: 2 days ago!

Summary

Product catalogue 2018
Air handling
units
Easy and flexible solutions for any ventilation requirements
ARGUE CARDS
Daikin air handling units
Why choose
Daikin air handling units? Benefits for the installer
›› Simple precise commissioning through
• Maximum energy efficiency pre-programmed DDC controller
›› Reduced installation time thanks to internal electrical wiring
and indoor air quality and external terminal connections avoiding drilling into unit
panels
• Wide range of functions and options ›› Flush mounted electrical control panel avoiding risk of damage
during transport and installation
• High quality components
• Innovative technology: Unique features and Benefits for the consultant
state of the art technology for short payback ›› Quick selection tool - in-house developed web software with
improved user interface allowing for a professional report in a
• Operation efficiency and energy savings few clicks
›› Unlimited configuration options
• Outstanding reliability and performance
• Various applications are possible including Benefits for the end user
air conditioning applications, industry-type ›› Energy efficient controls, allowing the user to determine a wide
range of settings, resulting in excellent operational flexibility
process cooling, and large-scale district ›› Safe operation - fully integrated electrical panel for units taller
than 80cm
heat source systems. ›› Amazing tailor made capability to meet the specific customer
needs
• Plug and play concept for easy installation and
commissioning
• Unique Daikin fresh air package available for
connection of AHU to VRV or ERQ
2
Marketing tools
Watch the time-lapse video of a Daikin AHU
construction on www.youtube.com/
daikineurope
›› Download our brochure on air handling units from
my.daikin.eu
›› Follow the wizard and select or modify your
Modular or Professional AHU in a few clicks!
Packaged control solution for Daikin AHU Plug and play design
›› Electrical control panel complete with Direct Digital ›› Low voltage fast connectors in between
Control (DDC) controller AHU sections
›› Internal fitting of all sensors and pressure
measurement devices Easy start-up and commissioning
›› Built-in temperature, humidity and CO2 sensors
›› Internal electrical wiring for all components ›› Pre-programmed and factory-tested controls ensuring
all wiring is installed correctly
Energy efficient while focusing ›› Reduced energy and operating costs
on maximum comfort
›› Set points can be specified for supply, Daikin Fresh air package
return or room temperature
›› Precise control of all AHU components such as ›› Plug and play connection of Professional or Modular R
mixing dampers, heat recovery wheels, water valves, AHU to Daikin VRV and ERQ
pressure switches for filters and fans, fan motors ›› Factory mounted package containis a.o. expansion
and inverters valve, electronic interface and sensors
›› Ensuring high efficiency and comfort
3
Air handling units
SMART CONTROLS
HEAT RECOVERY
DAMPER AND EC FAN WHEEL AND FILTER
4
Air handling units
D-AHU MODULAR R
INSTALLATION
COMFORTABLE
INDOOR CLIMATE
5
Air handling units
Products overview
D-AHU Professional
140
Air flow (m3/h x 1,000)
Professional
›› Pre-configured sizes
›› Tailored to the individual customer
120 ›› Modular construction
100
Modular R Modular P ›› Modular L
90 ›› Pre-configured sizes ›› Pre-configured sizes ›› Pre-configured sizes
›› Plug and play concept ›› Plug and play concept ›› Plug and play concept
›› EC fan technology ›› EC Fan technology ›› EC Fan technology
›› Heat recovery wheel ›› High efficiency alumin- ›› High efficiency alumin-
80
(sorption and sensible ium counter flow plate ium counter flow plate
›› technology) heat exchanger heat exchanger
›› Compact design ›› Compact design ›› Low height unit
70 ›› For false ceiling appli-
cations
60
50
40
D-AHU
Modular R D-AHU
20 Modular P D-AHU
Modular L
750 m3/h
up to 144,000 m3/h 500 m3/h 500 m³/h 100 m³/h
up to 25,000 m3/h up to 15,000 m³/h up to 3,400 m³/h
0
6
Air handling units
Selection software Quickly select your air handling unit by following the wizard:
ASTRA Web 1 Select the series: D-AHU Professional, D-AHU Modular R
›› Quick AHU selection that will save you precious time, drastically
reducing selection time through the new software interface. or D-AHU Modular P
›› Very competitive solution available within
the Wizard thanks to pre-uploaded parameters. 2   Insert the air flow supply and return
›› High selection quality, thanks to the intelligence embedded with-
in the software core. 3   Insert the summer/winter air supply setpoint
4   Insert the summer/winter outdoor and extract temperature
You will get immediately your 3D result and it’s ready to customize!
Now, you will be able to modify your unit (adding or changing
components) in order to have a product that meets all your needs

When finished a technical report, price list, fan curve chart and
psychrometric chart can be generated. These final reports can be
downloaded in different formats

Eurovent certification
Daikin Applied Europe S.p.A. participates in the
Eurovent Certified Performance programme for Air
Handling Units

Check ongoing validity of certificate:
www.eurovent-certification.com
or www.certiflash.com
AHU N°: 14.05.003
Range: D-AHU
Result sp65 Eurovent Classification according to EN1886
Casing strength class D1 D2 D3
D1
Max. relative deflection mm x m-1 4.00 10.00 EXCEEDING10
Casing air leakage class at -400 Pa L1 L2 L3
L1
Max. leakage rate (f400) l x s-1 x m-2 0.15 0.44 1.32
L1 Casing air leakage class L1 L2 L3
Max. leakage rate (f 700) l x s-1 x m-2 0.22 0.63 1.90
Filter bypass leakage class F9 F8 F7 F6 G1 TO F5
F9
Max. filter bypass leakage rate k in % of the volume flow rate 0.50 1 2 4 6
Thermal transmittance T1 T2 T3 T4 T5
T2
(U) W/m2 x K U <= 0.5 0.5 < U <= 1 1 < U <= 1.4 1.4 < U <= 2 No requirements
Thermal bridging factor TB1 TB2 TB3 TB4 TB5
TB2
(kb) W x m-2 x K-1 0.75 < Kb <= 1 0.6 < Kb <= 0.75 0.45 < Kb <= 0.6 0.3 < Kb <= 0.45 No requirements
7
Air handling units
The working principle at a glance
Typical configurations for Daikin air handling units
provide a versatile range of functions

Our system offers numerous options for
customisation through an extensive range of
variations and added functionality

11 10 9
Supply side
1 Damper section including ventilation
grilles, factory-mounted actuators
2 Bag filter with factory-mounted Exhaust air
differential pressure manometer and
hinged door
3 Heat recovery system
(plate heat exchanger or rotation heat
exchanger)
4 Mixing box with damper and factory-
mounted actuators
5 R-410A with heat recovery system with Fresh air
galvanised condensate tray and drip
protection
6 Supply air fan (with hinged door, opening,
drive monitoring, mounted and cabled
lighting and ON/OFF switch)
1 2 3 4
Fans Exchangers Humidifiers
›› EC plug fan ›› Water coils ›› Evaporative humidifier without pump (loss water)
›› Forward curved fan ›› Steam coils ›› Evaporative humidifier with re-circulating pump
›› Backward curved fan ›› Direct expansion coil ›› Air washer without pump (loss water)
›› Backward airfoil blades fan ›› Superheated water coils ›› Air washer with re-circulating pump
›› Plug fan ›› Electric coils ›› Steam humidifier with direct steam production
›› Steam humidifier with local distributor
›› Atomized water spray humidifier
8
Air handling units
Control system on plug and Unique section to section thermal break profile
play solution basis
›› Air temperature control ›› Thermal bridge free for the entire AHU
›› Chilled water and DX cooling system control ›› Smooth interior surface with improved IAQ
›› Free cooling (Indoor Air Quality)
›› CO2 automatic control
Common
Conventionaldesign
design New McQuay
Daikin designdesign
8 7
Return side
7 Bag filter with factory-mounted
differential pressure manometer
and hinged door

Return air
8 Exhaust air fan (with hinged
door, opening, drive monitoring,
mounted and cabled lighting and
ON/OFF switch)
9 Mixing box with damper and
factory-mounted actuators
10 Heat recovery system (plate heat
exchanger or rotation exchanger)
Supply air
11 Damper section including
ventilation grilles, factory-mounted
actuators
5 6
Heat recovery systems Other section Filters Accessories
›› Heat wheel, sensible or sorption ›› Attenuator section ›› Synthetic pleated filter ›› Control features
›› Plate heat exchanger (optional ›› Mixing box section ›› Flat filter aluminium mesh ›› Frost protection
bypass) with actuators or manual ›› Rigid bag filter ›› Manometers
›› Run-around coils controlled dampers ›› Soft bag filter ›› Drive guard
›› Empty section ›› High efficiency filter ›› Roof
›› Carbon absorption filter ›› …
›› Carbon deodorizing filter
9
Air handling units
Professional
Flexible solution for custom applications
Flexible design
Daikin Professional air handlers are tailored to
your needs, optimizing always the unit for the
most cost-effective selection and manufacturing
standardization

›› Air flow from 500 m³/h up to 144,000 m³/h

›› All the units can be modularly designed to facilitate
the transport and the assembly on site

Variable dimensioning
Size Airflow (m3/h) Height - mm Width - mm Size Airflow (m3/h) Height - mm Width - mm
1 1,800 640 720 12 29,800 1,690 2,480
2 2,200 640 810 13 33,800 1,870 2,510
3 3,500 740 980 14 43,200 1,990 2,940
4 5,400 840 1,190 15 51,000 2,110 3,230
5 6,600 840 1,390 16 63,000 2,290 3,620
6 7,600 940 1,390 17 68,000 2,290 3,890
7 9,000 1,090 1,380 18 77,000 2,290 4,410
8 11,000 1,150 1,550 19 87,000 2,410 4,660
9 14,000 1,270 1,720 20 95,400 2,470 4,960
10 18,300 1,390 1,970 21 111,200 2,590 5,460
11 23,800 1,570 2,190 22 127,000 2,650 6,060
Example
›› 1 cm increment for width & height dimensions Airflow Unit Size Height Width Face
›› No additional cost for customized unit size (m3/h) (mm) (mm) Velocity
›› No additional lead time (m/s)
Size 15 2,110 3,230 2.27
47,000
1,920x2,720 2,110 2,950 2.5
Plug and play: More control, more flexibility
The plug and play control system allows for more for filters and fans, fan motors and inverters

precise control than ever before, allowing the user All these components are wired internally and
to determine a wide range of settings, resulting in individual AHU modules are linked by fast connectors

excellent operational flexibility. The AHU control system can manage the chilled
The factory-fitted electrical control panel, water coil, hot water coil, DX cooling and/or heating
complete with Direct Digital Control (DDC) is coil(s) (in conjunction with ERQ/VRV) of single
combined with in-built temperature, humidity or multiple refrigerant circuits (up to a maximum
and CO2 sensors to control mixing dampers, of four circuits per DX coil)

heat recovery wheels, water valves, pressure switches
10

Air handling units 3 Air flow (m /h x 1,000) 0 20 40 50 60 70 80 90 100 120 140 D-AHU Professional 750 m3/h up to 144,000 m3/h Modular P › Pre-configured sizes › Plug and play concept › EC Fan technology

Air handling units 3 Air flow (m /h x 1,000) 0 20 40 50 60 70 80 90 100 120 140 D-AHU Professional 750 m3/h up to 144,000 m3/h Modular P › Pre-configured sizes › Plug and play concept › EC Fan technology › High efficiency alumin-ium counter flow plate heat exchanger › Compact design D-AHU Modular R D-AHU Modular P D-AHU Modular L 500 ...

Frequently Asked Questions

Why choose daikin air handling units?

Product catalogue 2018 Air handling units Easy and flexible solutions for any ventilation requirements Product catalogue 2018 Air handling units ARGUE CARDS Daikin air handling units Why choose Daikin air handling units? • Maximum energy efficiency and indoor air quality • Wide range of functions and options • High qualitycomponents

What is included in daikin ahu packaged control solution?

Packaged control solution for Daikin AHU ›Electrical control panel complete with Direct Digital Control (DDC) controller › Internal fitting of all sensors and pressure measurement devices › Built-in temperature, humidity and CO 2 sensors › Internal electrical wiring for all components

What is included in the daikin fresh air package?

13 Plug and play connection of AHU to Daikin VRV and ERQ The Daikin fresh air package provides a complete solution, including all unit controls (expansion valve, control box and AHU controller) and sensors factory mounted and configured. Higher efficiency Daikin heat pumps are renowned for their high energy efficiency.

Download Now Error Report

Please leave your comments here:

 

Popular Search

About Us

The display of third-party trademarks and trade names on this site does not necessarily indicate any affiliation or endorsement of librarytemplates.com.

If you click a merchant link and buy a product or service on their website, we may be paid a fee by the merchant.

©2021 Copyrights. All rights reserved. Librarytemplates.com

Newsletter

Subscribe to receive news from us.